MIEKA MIE-SP5 ve MIE-SP8 Hırsız Alarm Panellerinde Uo Programlanabilir Çıkış Kullanımı



MIEKA MIE-SP5 ve MIE-SP8 hırsız alarm panelleri 33 farklı moda programlanabilen , Uo olarak adlandırılan çıkışa sahiptirler. AUX+ ve Uo arasına bağlandığında çeşitli aygıtlar kontrol edilebilmektedir. Uo çıkışı 70mA akım verebilme kapasitesine sahiptir.   



Uo Programlanabilir çıkışı 22. program adresinde bulunmaktadır.


22 ARM [ Tablodan Değer Seç ] #


Örn. Uo siren çıkışı siren çalıyorken aktif olması için 22 ARM 04 # girilmelidir.



Dijit
Olay ve Sonuç
00 (Fabrika Çıkışı)
Not Active
UO offers no response to any system activity UO
01
preparation
02
Arm Follow (Latch)
UO is activated when the system is armed. The activation occurs after the expiration of the exit/delay period. The UO remains active (latched) while the system is armed. When disarming the system the UO deactivates (Unlatches).
03
Arm Follow (Pulse)
UO is activated when the system is armed .The activation occurs after the expiration of the exit/delay period. The UO is activated for several seconds (pulse), after which is deactivated.
04
Alarm Follow (Latched)
UO is immediately activated when the system goes into any type of alarm (i.e. intrusion, fire, keypad-initiated panic) UO remains active (latched) for the duration of the alarm-even after the system's sounder "times out" UO is deactivated when the system is disarmed.
05
Alarm Follow (Pulse)
UO is immediately activated of several seconds and then deactivated whenever the system goes into any type of alarm (i.e. intrusion, fire, keypad-initiated panic)
06
Panic Follow (Latched)  
UO is activated immediately when a PANIC alarm is triggered by a violation of a zone, defined as Panic, or by pressing the keypad's [1] and [2] keys simultaneously for two seconds. UO is deactivated when the system is disarmed.
07
Panic Follow (Pulse)
UO is activated for several seconds when a PANIC alarm is triggered by a violation of a zone, defined as Panic, or by pressing the keypad's [1] and [2] keys simultaneously for two seconds.
08
Fire Keying Follow (Latched)
UO is activated immediately when a Fire alarm is triggered by a violation of zone 5, defined as Fire, or by pressing the keypad's [4] and [5] keys simultaneously for two seconds, UO is deactivated when the system is disarmed.
09
Fire Keying Follow (Pulse)
UO is activated when a Fire alarm is triggered by violation of zone 5, defined as Fire, 0r by pressing the keypad's [4] and [5] keypad's simultaneously for two seconds.
10
Special Emergency Keying Follow (Latched)
UO is activated immediately when pressing the keypad's [7] and [8] keys simultaneously for two seconds. UO is deactivated when the system is disarmed.
11
Special Emergency Keying Follow (Pulsed)
UO is activated for several seconds when pressing the keypad's [7] and [8] keys simultaneously for two seconds.
12
Duress Code Follow(Pulse)
UO is activated for several seconds (and then deactivates) when any duress code is entered.
13
Duress Code Follow (Latched)
UO is activated when any duress code is entered.
14
AC Loss Follow (Latched)
UO is activated due to a lack of power from the commercial AC. UO is deactivated when the system is operating properly from commercial (AC) power.
15
AC Loss Follow (Pulse) AC
UO is activated for several seconds (and then deactivates) due to a lack of power from the commercial AC.
16
Low Battery Follow (Latched)
UO is activated due to low power from the backup battery. UO1 is deactivated when the battery is in good condition.
17
Low Battery Follow (Pulse)
UO is activated for several seconds due to low power from the backup battery.
18
Zone 1 Alarm Follow (Latched)
UO is immediately activated when an alarm occurs on Zone 1. UO remains active (latched) for the duration of the alarm-even after the system sounder "times out". UO is deactivated when Zone 1 goes into normal condition.
19
Zone 1 Alarm Follow(Pulse)
UO is immediately activated for several seconds (pulse) and then deactivates whenever Zone 1 goes into alarm.
20
Zone 2 Alarm Follow(Latched) 
21
Zone 2 Alarm Follow(Pulse)   
22
Zone 3 Alarm Follow(Latched) 
23
Zone 3 Alarm Follow(Pulse)   
24
Zone 4 Alarm Follow(Latched) 
25
Zone 4 Alarm Follow(Pulse)   
26
Zone 5 Alarm Follow(Latched) 
27
Zone 5 Alarm Follow(Pulse)   
28
Zone 6 Alarm Follow(Latched) 
29
Zone 6 Alarm Follow(Pulse)   
30
Zone 7 Alarm Follow(Latched) 
31
Zone 7 Alarm Follow(Pulse)   
32
Zone 8 Alarm Follow(Latched) 
33
Zone 8 Alarm Follow(Pulse)   